BEST DIY EXTERIOR LED LIGHTS

EVERLIGHTS v3 Starter Kit + Lights in 25' ft lengths

*NOTE* Channel, receivers, boosters, buffers, y-spliters, tape, and connectors all sold seperately.

1 People are viewing this product now.
WAS $783.00 NOW $650.00
Qty
Cap color
Length

PRODUCT DESCRIPTION

These bundles only include (1) Color Changing v3 RGB Starter Kit with LED Lights by the foot. Select the Length needed, Cap color, then add to cart and you're done.

As a reminder: Based on your projects roofline layout plan, you may need to add additional items from your material list below or in the popup side cart.

The general guidelines are:

  • @ 100' add (1) Power Booster (2) Data Buffers (1) Y-Split
  • @ 150' add (2) Power Boosters (3) Data Buffers (2) Y-Splits
  • @ 200' add (3) Power Boosters (4) Data Buffers (3) Y-Splits
  • Add Data Buffers @ Y-Splits & Unlit wire jumps longer then 5'
  • Add Power Boosters over 75'
  • Add Wireless Receivers to add zones

EVERLIGHTS makes no claim, express or implied, of a wireless connectivity guarantee.

Use of this product may require maintenance, including but not limited to, re-establishing connectivity or replacing light bulbs.

MATERIAL LIST ADDERS:

Select the items dropdown variation first before you tick the checkbox. To save time simply add any additional items needed from your material list below, then change the quantities in the side cart when it slides open.

Wireless LED Receiver $175.00 $150.00
LED Data Buffer $12.00 $10.00

DIY ESTIMATING TIPS

MEASURE ALL EVES AND GUTTERS

& always round up

HOW TO MEASURE PROJECT: VIDEO

Timelaps Install of channel & to gutters - Time: 00:38

The 3 Must Follow Rules For A Proper Install 

If all else fails, follow these rules and you will be OK. 

1) Never cut any wires with the lights powered. The lights are powered anytime they are plugged into a power source, whether the lights are on or not. Always install with the lights unplugged from all power sources. 
2) Connect like to like wires. The wire labeled “EverLights” only connects to other wires labeled “EverLights”. Same deal for the other two wires. 
3) Keep the direction of the lights constant. Every light has an input and output. They must always connect in to out. The back of every light is labeled and includes an arrow. Ensure all arrows are pointing in the same direction. 

Failure to follow these rules will result in an increased failure rate because of improper power flow. 



TERMINATING WIRE RUNS

Wherever you decide to terminate a run of lights it is very important to properly protect the exposed wires. There are multiple methods to coat the end of the wires, but generally electrical tape, silicone, or liquid electrical tape work best. The purpose of coating the wires is to prevent the positive and wires from coming in contact through water, touching against a piece of metal, or any other conductive material.


A short in the lights will cause improper function and potential damage to the lights in the system. To further protect against a potential short, snip the positive wire an inch shorter than the other wires before coating.

PRODUCT REVIEWS

No Review Found

Quick links

Contact Us

Phone: 702.353.7003

[email protected]

All Orders Ship From:

Lindon UT

We accept